June 25, 2013

FDA approves human feasibility study of device for treatment of HCV

Provided by Healio

June 25, 2013

The FDA has approved an investigational device exemption for a human feasibility study of a medical device for treating patients with hepatitis C, according to a press release.

The Aethlon Hemopurifier (Aethlon Medical) is intended for use in combination with interferon-based therapy or antiviral treatments, to improve early viral kinetic response without introducing additional drug toxicity. The device includes a plasma membrane containing immobilized affinity lectin Galanthus nivalis agglutinin, and allows extracorporeal therapeutic delivery through instruments currently available in medical facilities. According to the release, the Hemopurifier would benefit patients who experience viral rebound and require treatment discontinuation, as well as in those for whom standard or antiviral therapy is contraindicated.

Planned testing for the device will include the enrollment of 10 patients with end-stage renal disease (ESRD) and HCV infection. Participants will have received no pharmaceutical HCV therapy within the previous 30 days or longer. After a control phase of three dialysis treatments over 1 week, patients will subsequently receive Hemopurifier therapy during six dialysis sessions across 2 weeks. Incidence of adverse events will be compared between the control and Hemopurifier phases, and change to viral load during treatment will be assessed.

Prior studies outside of the United States indicated that Hemopurifier use was well tolerated among treatment-naive, HIV/HCV coinfected patients with ESRD when added to standard dialysis, decreasing viral loads from both diseases by an average of more than 50% per treatment. Additional studies of patients with HCV and without ESRD, in which three Hemopurifier treatments were administered in combination with interferon-based therapy, led to undetectable HCV viral loads within as few as 7 days among participants with HCV genotype 1.

“Aethlon Medical has been laying the groundwork necessary to implement the now approved clinical trial protocol for several years,” Rod Kenley, company president, said in the release. “While there is still some work to be done, today the biggest hurdle has been cleared, and we are anxious to make rapid progress toward commercialization.”

Source

Also See: Aethlon Medical Announces FDA Approval of IDE to Treat Hepatitis C (HCV) Patients

Aethlon Medical Announces FDA Approval of IDE to Treat Hepatitis C (HCV) Patients

AETHLON MEDICAL HEMOPURIFIER

SAN DIEGO, June 25, 2013 /PRNewswire/ -- Aethlon Medical, Inc. (OTCQB: AEMD), announced today that the United States Food and Drug Administration (FDA) has approved an Investigational Device Exemption (IDE) that allows the Company to initiate human feasibility studies of the Aethlon Hemopurifier® in the United States. The Hemopurifier® is a first-in-class medical device that targets the rapid elimination of life-threatening infectious disease and cancer glycopathogens from circulation.

(Photo: http://photos.prnewswire.com/prnh/20090325/LA88762LOGO-b)

Under the feasibility study protocol, Aethlon will enroll ten end stage renal disease (ESRD) patients who are infected with the Hepatitis C virus (HCV) to demonstrate the safety of Hemopurifier therapy. Successful completion of the feasibility study will set the stage for Aethlon to conduct pivotal studies required for market clearance to treat HCV and potentially other disease conditions.

"Obtaining FDA's permission to initiate human studies has been our most important objective for several years," stated Jim Joyce, Chairman and CEO of Aethlon Medical. "I salute the perseverance of our dedicated Aethlon team, their families, and loyal shareholders whose support allowed us to endure the challenges of navigating through FDA. We plan to reward your faith with clinical execution and progression toward a marketable therapy in the United States."

Specific to the treatment of HCV, the Hemopurifier is uniquely positioned as an adjuvant to be incorporated with either interferon-based standard of care (SOC) or emerging all-antiviral drug regimens without adding drug toxicity.  In addition to augmenting the early viral kinetic response to SOC, the Hemopurifier is a candidate solution for viral rebound patients who traditionally are forced to discontinue therapy at the point HCV establishes resistance to drug regimens. Additionally, the Hemopurifier addresses the large population of HCV-infected ESRD patients for which SOC and emerging all-antiviral strategies may be contraindicated or not yet cleared.  According to the World Health Organization (WHO), HCV is a blood-borne pathogen that affects upwards of 170 million persons, or 2-3% of the world's population. It is a leading cause of cirrhosis and liver transplantation.

The FDA approved Hemopurifier therapy feasibility study calls for a single-site enrollment of ten HCV-infected end-stage renal disease (ESRD) patients who have not received any pharmaceutical therapy for their HCV infection for at least 30 days.  The protocol consists of a control phase which consists of three consecutive standard dialysis treatments during week one followed by the inclusion of the Hemopurifier during a total of six dialysis sessions conducted during weeks two and three. The rate of adverse events observed during the Hemopurifier therapy phase will be compared to the rate experienced during the control phase. Per-treatment changes of viral load will be observed through quantitative PCR analysis. Additionally, Aethlon may also choose to quantitate HCV viral copies captured within the Hemopurifier during each treatment session.

In studies previously conducted in India, Hemopurifier therapy was demonstrated to be well tolerated in treatment naïve HIV and HCV-infected ESRD patients when included during normally scheduled four-hour dialysis sessions. In these studies, average per treatment viral load reductions were observed to exceed 50% in both disease conditions.  In follow-on studies of non-ESRD individuals infected with HCV, a three-treatment protocol of Hemopurifier therapy in combination with interferon-based standard of care (SOC) resulted in undetectable HCV in as little as seven days in hardest to treat genotype-1 patients.  The studies also documented the ability of the Hemopurifier to capture as many as 300 billion HCV copies during a single six-hour treatment.

"Aethlon Medical has been laying the groundwork necessary to implement the now approved clinical trial protocol for several years" said Rod Kenley, Aethlon's President. "We are finally able to move forward with our contract research and clinical partners in finalizing all of the activities that can now take place prior to initiating treatment of the first patient.  While there is still some work to be done, today the biggest hurdle has been cleared and we are anxious to make rapid progress towards commercialization."

The feasibility study protocol was originally designed as a human safety challenge and model for addressing drug and vaccine resistant bioterror and emerging pandemic threats such as the Middle East Respiratory Syndrome (MERS) now spreading overseas.  In vitro studies conducted by leading government and non-government researchers have demonstrated that the Hemopurifier is able to capture a broad-spectrum of some of world's deadliest viral pathogens.  These include: Dengue hemorrhagic fever (DHF), Ebola hemorrhagic fever (EHF), Lassa hemorrhagic fever (LHF), H5N1 avian influenza (Bird Flu), H1N1 swine flu virus, the reconstructed 1918 influenza virus (r1918), West Nile virus (WNV) and Vaccinia and Monkeypox (MPV), which serve as models for human smallpox infection.  Human efficacy studies are not permissible against high-threat bioterror and pandemic threats.

The Hemopurifier is also being tested for its ability to capture glycopathogen targets that initiate or enhance the progression of sepsis through a contract with the Defense Advanced Research Projects Agency (DARPA). Sepsis is a life-threatening illness triggered by an overwhelming infection of the bloodstream. Globally, there are 18 million cases of diagnosed sepsis per year and the incidence is rising at 8 to 10% annually. 

In cancer, the Hemopurifier has been discovered to capture tumor-derived exosomes underlying several forms of cancer.  Tumor-derived exosomes have recently emerged to be a vital therapeutic target in cancer care. These microvesicular particles suppress the immune response in cancer patients through apoptosis of immune cells and their quantity in circulation correlates directly with disease progression. Beyond possessing immunosuppressive properties, tumor-derived exosomes facilitate tumor growth, metastasis, and the development of drug resistance.  By addressing this unmet medical need, the Hemopurifier is positioned as an adjunct to improve established cancer treatment regimens. In vitro studies to date have also documented that the Hemopurifier captures exosomes underlying lymphoma, melanoma, ovarian, and breast cancer.

In design, the Aethlon Hemopurifier consists of the affinity lectin Galanthus nivalis agglutinin (GNA) immobilized in the outer-capillary space of advanced plasma membrane technology. The design allows for extracorporeal therapeutic delivery to occur on standard CRRT and dialysis instruments already located in hospitals and clinics worldwide. The mechanism of the Hemopurifier to rapidly eliminate a broad-spectrum disease targets is based on GNA's ability to selectively bind unique high mannose signatures that are abundant on the surface of cancer-secreted exosomes and glycoproteins that reside on the outer membrane of infectious viral pathogens.

The Company will continue to update shareholders, constituents and potential study participants as feasibility study milestones are achieved, including naming a principal investigator, initiation of patient enrollment and the beginning of treatments with the Aethlon Hemopurifier.

About Aethlon Medical
Aethlon Medical creates innovative medical devices that address unmet medical needs in cancer, infectious disease, and other life-threatening conditions. Our Aethlon ADAPT™ System is a revenue-stage technology platform that provides the basis for a new class of devices the rapid, yet selective removal of disease promoting particles from the entire circulatory system.  At present, The Aethlon ADAPT product pipeline includes the Aethlon Hemopurifier to address infectious disease and cancer, and a medical device being developed under a 5-year contract with DARPA to reduce the incidence of sepsis in combat-injured soldiers.  For more information, please visit www.aethlonmedical.com.

Certain statements herein may be forward-looking and involve risks and uncertainties.  Such forward-looking statements involve assumptions, known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of Aethlon Medical, Inc. to be materially different from any future results, performance, or achievements expressed or implied by the forward-looking statements. Such potential risks and uncertainties include, without limitation, that the FDA will not approve the initiation of the Company's future clinical programs or provide market clearance of the Company's products, future human studies whether revenue or non-revenue generating from either compassionate use or non-compassionate use of the Aethlon ADAPT™ system or the Aethlon Hemopurifier® as an adjunct therapy to improve patient responsiveness to established cancer or hepatitis C therapies or sepsis therapies or as a standalone cancer or hepatitis C therapy or standalone sepsis therapy, the approval of the Company's technologies or products as a treatment against pandemic threats, the Company's ability to raise capital when needed, the Company's ability to complete the development of its planned products, the Company's ability to manufacture its products either internally or through outside companies and provide its services, the impact of government regulations, patent protection on the Company's proprietary technology, product liability exposure, uncertainty of market acceptance, competition, technological change, and other risk factors. In such instances, actual results could differ materially as a result of a variety of factors, including the risks associated with the effect of changing economic conditions and other risk factors detailed in the Company's Securities and Exchange Commission filings. The Company undertakes no obligation to publicly update or revise any forward-looking statements, whether as a result of new information, future events, or otherwise.

Contacts:
James A. Joyce
Chairman and CEO
858.459.7800 x301
jj@aethlonmedical.com

Jim Frakes
Chief Financial Officer
858.459.7800 x300
jfrakes@aethlonmedical.com

Marc Robins
877.276.2467
mr@aethlonmedical.com

SOURCE Aethlon Medical, Inc.

RELATED LINKS
http://www.aethlonmedical.com

Source

May 8, 2013

Aethlon Medical (AEMD) Note: An Update on the Clinical Status of the Aethlon Hemopurifier® in Hepatitis-C Care

logo-prn-01_PRN

SAN DIEGO, May 7, 2013 /PRNewswire/ -- Aethlon Medical, Inc. (OTCQB: AEMD), today released the following note authored by its Chairman and CEO, Jim Joyce .

Through the publication of CEO notes, I seek to provide shareholders and other interested parties with a level of corporate transparency often absent in the microcap marketplace. In recent notes, I reviewed various topics, including emerging opportunities in cancer and the expansion of our government contract program to create a sepsis therapeutic.

This note is specific to our most important near-term objective: the approval of a investigational device exemption (IDE) by the U.S. Food and Drug Administration (FDA) that would allow us to initiate clinical feasibility studies of Hepatitis-C (HCV) infected individuals receiving Hemopurifier® therapy. In this regard, FDA withheld clearance of our recently amended IDE based on a single information deficiency that was deemed a safety concern. Specifically, FDA has requested that we detail our training and monitoring procedures related to heparinization, which is the primary anticoagulant utilized in dialysis and other extracorporeal therapies, including our Hemopurifier®. We are assembling the requested information and expect to have our response back in the hands of FDA in the coming week. The approval of our IDE remains a critical step in our strategy to advance a first-in-class medical device to address a major-market infectious disease condition.

HCV is a blood-borne pathogen that affects upwards of 170 million persons, or 2-3% of the world's population. It is a leading cause of liver cirrhosis and transplant and there is no pre or post infection vaccine. The magnitude of the HCV therapeutic opportunity has spawned immense competition within the drug industry. According to citeline®, there are over 200 planned and ongoing Phase I-III trials of pipeline HCV drugs as of March 1, 2013. However, it should be noted that only ten companies are responsible for 83% (165/200) of the referenced HCV studies; Bristol-Myers Squibb, Gilead, Merck & Co., AbbVie, Boehringer Ingelheim, Johnson & Johnson, Roche, Vertex, Achillion and Novartis. A primary factor for this odd statistical imbalance is the reality that these organizations often acquire candidate therapies that demonstrate clinical promise.

As a medical device, we have an enduring opportunity as our Hemopurifier® is uniquely positioned as an adjuvant to either interferon-based standard of care (SOC) or emerging all-antiviral drug regimens. And, unlike adjunct drug strategies, the Hemopurifier® performs without adding drug toxicity. In studies conducted in India, a three-treatment Hemopurifier® protocol administered in combination with interferon-based SOC resulted in undetectable HCV levels in as little at seven days in hard to treat genotype-1 patients. The studies also documented the ability of the Hemopurifier® to capture as many as 300 billion copies of HCV during a single six-hour treatment. In addition to augmenting the early viral kinetic response to drug therapy, the Hemopurifier® is a candidate solution for viral rebound patients who traditionally are forced to discontinue therapy once HCV establishes resistance to their drug regimens. Such a solution would address a significant unmet medical need in HCV care.

In closing, we are confident that we can fulfill FDA's information request. In the interim, I remain grateful to loyal shareholders that support our cause and I salute the continued perseverance of my Aethlon teammates.

About Aethlon Medical

Aethlon Medical creates innovative medical devices that address unmet medical needs in cancer, infectious disease, and other life-threatening conditions. Our Aethlon ADAPT™ System is a revenue-stage technology platform that provides the basis for a new class of devices the rapid, yet selective removal of disease promoting particles from the entire circulatory system. At present, The Aethlon ADAPT™ product pipeline includes the Aethlon Hemopurifier® to address infectious disease and cancer, and a medical device being developed under a 5-year contract with Defense Advanced Research Projects Agency (DARPA) to reduce the incidence of sepsis in combat-injured soldiers. For more information, please visit www.aethlonmedical.com.

About The Aethlon Hemopurifier®

The Aethlon Hemopurifier® is a first-in-class medical device that selectively targets the rapid clearance of infectious viral pathogens and immunosuppressive proteins from the entire circulatory system. In the treatment of Hepatitis C virus (HCV), human studies have demonstrated that Hemopurifier® therapy may improve immediate, rapid and sustained virologic response rates when administered in the first few days of standard-of-care drug therapy. In addition to accelerating viral load depletion, post-treatment analysis of the Hemopurifier® has documented the capture of up to 300 billion HCV copies of HCV during a single six-hour treatment. Access to Hemopurifier® therapy is available on a compassionate-use basis through the Medanta Medicity Institute (Medicity), a leading center for medical tourism in India. The Medicity is offering treatment access to infected individuals who previously failed or subsequently relapsed standard-of-care drug regimens. The Hemopurifier® is also being offered as a salvage therapy to infected individuals who suffer a viral breakthrough during standard-of-care therapy. U.S. studies of the Hemopurifier® are currently pending approval of an IDE submitted to FDA.

The Aethlon Hemopurifier® and Cancer

In addition to the opportunity to address a broad-spectrum of infectious viral pathogens, the Hemopurifier® has been discovered to capture tumor-derived exosomes underlying several forms of cancer. Tumor-derived exosomes have recently emerged to be a vital therapeutic target in cancer care. These microvesicular particles suppress the immune response in cancer patients through apoptosis of immune cells and their quantity in circulation correlates directly with disease progression. Beyond possessing immunosuppressive properties, tumor-derived exosomes facilitate tumor growth, metastasis, and the development of drug resistance. By addressing this unmet medical need, the Hemopurifier® is positioned as an adjunct to improve established cancer treatment regimens.

Certain statements herein may be forward-looking and involve risks and uncertainties. Such forward-looking statements involve assumptions, known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of Aethlon Medical, Inc. to be materially different from any future results, performance, or achievements expressed or implied by the forward-looking statements. Such potential risks and uncertainties include, without limitation, that the FDA will not approve the initiation of the Company's clinical programs or provide market clearance of the company's products, future human studies whether revenue or non-revenue generating from either compassionate use or non-compassionate use of the Aethlon ADAPT™ system or the Aethlon Hemopurifier® as an adjunct therapy to improve patient responsiveness to established cancer or hepatitis C therapies or sepsis therapies or as a standalone cancer or hepatitis C therapy or standalone sepsis therapy, the Company's ability to raise capital when needed, the Company's ability to complete the development of its planned products, the Company's ability to manufacture its products either internally or through outside companies and provide its services, the impact of government regulations, patent protection on the Company's proprietary technology, product liability exposure, uncertainty of market acceptance, competition, technological change, and other risk factors. In such instances, actual results could differ materially as a result of a variety of factors, including the risks associated with the effect of changing economic conditions and other risk factors detailed in the Company's Securities and Exchange Commission filings. The Company undertakes no obligation to publicly update or revise any forward-looking statements, whether as a result of new information, future events, or otherwise.

Contacts:

James A. Joyce
Chairman and CEO
858.459.7800 x301
jj@aethlonmedical.com

Jim Frakes
Chief Financial Officer
858.459.7800 x300
jfrakes@aethlonmedical.com

Marc Robins
877.276.2467
mr@aethlonmedical.com

SOURCE Aethlon Medical, Inc.

RELATED LINKS
http://www.aethlonmedical.com

Source

October 2, 2012

Aethlon Medical Releases Hepatitis C Virus (HCV) Treatment Protocol and Inclusion/Exclusion Criteria Underlying Compassionate-Use Commercialization Program

logo

SAN DIEGO, Oct. 2, 2012 /PRNewswire/ -- Aethlon Medical, Inc. (OTCBB: AEMD), the pioneer in developing selective therapeutic filtration devices to address infectious disease, cancer and other life-threatening conditions, today released the treatment protocol underlying a program that will provide hard-to-treat HCV-infected individuals with expanded access to Hemopurifier® therapy. The Company also disclosed inclusion and exclusion criteria for candidate patients as well as details on the physicians who will administer the program, which is expected to generate first product sales of the Aethlon Hemopurifier®.

(Photo: http://photos.prnewswire.com/prnh/20090325/LA88762LOGO-b)

The Aethlon Hemopurifier® is a first-in-class medical device with broad-spectrum capability to address infectious viral pathogens and immunosuppressive exosomes underlying cancer and other life-threatening conditions. In the expanded access program, Hemopurifier® therapy will be administered to selectively target the rapid clearance of HCV from the entire circulatory system to improve benefit, dose, duration and tolerability of standard-of-care drug therapy. The program is being initiated with support from the Institutional Review Board at the Medanta Medicity Institute (Medicity) to allow compassionate usage of the Aethlon Hemopurifier® for individuals who previously failed or subsequently relapsed standard-of-care drug regimens. The Medicity is a leading center for medical tourism in India.

In addition to offering Hemopurifier® therapy to the citizens of India, HCV-infected individuals from the United States, European Union and other regions of the world may pursue treatment through the expanded access program. It is estimated that approximately 170 million people worldwide are infected with HCV, which leads to chronic liver disease or cirrhosis, and is a leading cause of liver transplantation.

"We are grateful for the opportunity to provide hard-to-treat HCV-infected individuals with access to Hemopurifier® therapy," stated Aethlon Chairman and CEO, Jim Joyce. "Beyond advancing our therapeutic objectives, the resulting Hemopurifier® product sales will augment the government contract revenue stream we established this past year."

The Medicity Expanded Access Treatment Protocol

The Medicity expanded access program will offer HCV-infected individuals the option of either a 3-day or 7-day Hemopurifier® therapy regimen. Under each regimen, Hemopurifier® therapy will be administered continuously for a period up to six hours on each treatment day. While there will be a difference in cost, Hemopurifier® therapy underlying both regimens will be initiated in combination with standard-of-care drug therapy. The treatment objective will be to accelerate the rate and increase the likelihood that patients achieve undetectable HCV RNA. Details related to therapy pricing and candidate patient enrollment processes at the Medicity are anticipated in the coming weeks.

Candidate Patient Inclusion Criteria

  • Males or females 18 years of age and older testing positive for any HCV genotype
  • HCV-infected individuals that have relapsed after completing a previous course of standard-of-care drug therapy
  • Null responders or individuals who previously were unable to achieve > 2 log viral load reduction at month three of standard of care drug therapy
  • Candidate patients must be willing to submit to temporary vascular access catheterization
  • Ability to tolerate blood volume losses of up to 150 ml per week
  • Stable clinical condition, including stable hematocrit
  • Individuals on ACE inhibitors must suspend ACE inhibitor administration for a minimum of six days prior to initiating therapy
  • Karnofsky score ≥ 60
  • Details of blood chemistry inclusion criteria will be provided to candidate patients who meet the above criteria
  • Candidate patients will be required to sign a written informed consent prior to enrollment in the treatment access program

Candidate Patient Exclusion Criteria

  • Clinically significant infection, other than HCV, defined as any acute viral, bacterial, or fungal infection, which requires specific therapy (Anti-infectious therapy must have been completed at least 14-days before entry into study)
  • Co-infections with Hepatitis B virus and Human immunodeficiency virus (HIV)
  • Received any investigational drug agent(s) within 28-days of entry into study
  • Any known pre-existing medical condition that could interfere with the subject's participation in the protocol, including serious psychiatric disorders, CNS trauma or active seizure disorders requiring medication, poorly controlled diabetes mellitus, significant cardiovascular dysfunction within the past 6 months (e.g., angina, congestive heart failure, recent myocardial infarction, severe hypotension, or significant arrhythmia)
  • Subjects with ECG showing clinically significant abnormalities
  • Need for frequent blood transfusions.
  • Recent History of bleeding or bleeding disorders requiring the restriction in use of anticoagulants during study treatments.
  • Active immunologically mediated disease (e.g., inflammatory bowel disease [Crohn's disease, ulcerative colitis], rheumatoid arthritis, idiopathic thrombocytopenia purpura, systemic lupus erythematosus, autoimmune or inherited hemolytic anemia, scleroderma, severe psoriasis)
  • Any medical condition requiring, or likely to require during the course of the study, chronic systemic administration of steroids or other immune-regulatory medications
  • Substance abuse, such as alcohol (~80 gm/day), IV drugs, and inhaled drugs (If the subject has a history of substance abuse, to be considered for inclusion into the protocol, the subject must have abstained from using the abused substance for at least 2 months
  • Any cancer requiring systemic chemotherapy
  • Any other condition that, in the opinion of the principal investigators or treating physicians, would make the subject unsuitable for enrollment, or could interfere with the subject participating in and completing the expanded access protocol

Current HCV Studies

In addition to the forthcoming expanded access program, Aethlon has been conducting a study at the Medicity which is evaluating the capability of the Aethlon Hemopurifier® to accelerate HCV RNA depletion at the outset of standard of care peginterferon+ribavirin (PR) therapy. Specifically, HCV-infected individuals are enrolled to receive up to three, six-hour Hemopurifier® treatments during the first three days of PR drug therapy. Aethlon recently reported that two HCV-infected patients who received Hemopurifier® therapy in combination with PR drug therapy achieved undetectable viral load at day-7, which is rarely reported in drug therapy alone.

A primary clinical endpoint of the Medicity protocol has been to increase the incidence of rapid virologic response (RVR), defined as undetectable HCV RNA at day 30 of therapy. RVR represents the clinical endpoint that best predicts treatment cure, otherwise known as sustained virologic response (SVR), defined as undetectable HCV RNA 24-weeks after the completion of PR drug therapy. As a point of reference, the landmark IDEAL Study of 3,070 HCV genotype-1 patients documented that only 10.35% (n=318/3070) of PR treated patients achieved a RVR. However, patients that achieved a RVR had SVR rates of 86.2% (n=274/318) versus SVR rates of 32.5% (n=897/2752) in non-RVR patients. While the incidence of undetectable HCV RNA at day-7 is not reported in the IDEAL study, the study did reveal that just 4.3% (n=131/3070) of patients achieved undetectable HCV RNA at day-14, which equated to a 91% (n=118/131) SVR rate.

Aethlon reported that Hemopurifier® therapy has been well tolerated and without device-related adverse events in ten treated patients. Of these ten patients, seven patients were infected with HCV genotype-1; two patients were infected with HCV genotype-3; and one patient was infected with HCV genotype-5. At present, undetectable HCV RNA is reported in eight of the 10 treated patients. Of the two patients with detectable HCV RNA, one discontinued PR therapy as a result of a diabetes related condition. HCV RNA is undetectable in all patients (n=4) that have been monitored for 48 weeks since receiving Hemopurifier® therapy. Among the 10 treated patients, Aethlon reported that six genotype-1 patients received the three treatment Hemopurifier® protocol, which resulted in four (67%) patients achieving a RVR. The IDEAL study predicts it would normally require approximately 40 PR treated patients to achieve 4 RVR outcomes. Both patients who achieved undetectable HCV RNA at day-7 also achieved a RVR. Beyond the high likelihood of a SVR, genotype-1 patients that achieve a RVR also have the opportunity to reduce the duration of PR drug therapy from 48 weeks to 24 weeks.

About Medanta – The Medicity

Medanta – The Medicity is one of India's largest multi-super specialty institutes located in Gurgaon, a bustling town in the National Capital Region. Founded by eminent cardiac surgeon, Dr. Naresh Trehan, the institution has been envisioned with the aim of bringing to India the highest standards of medical care along with clinical research, education and training. Medanta is governed under the guiding principles of providing medical services to patients with care, compassion and commitment.

Spread across 43 acres, the institute includes a research center, medical and nursing school. It has 1250 beds and over 350 critical care beds with 45 operation theatres catering to over 20 specialties. Medanta houses six centers of excellence, which provide medical intelligentsia, cutting-edge technology and state-of-the-art infrastructure with a well-integrated and comprehensive information system. The Medicity brings together an outstanding pool of doctors, scientists and clinical researchers to foster collaborative, multidisciplinary investigation, inspiring new ideas and discoveries; and translating scientific advances more swiftly into new ways of diagnosing and treating patients and preventing diseases. A one-of-its-kind facility across the world, Medanta through its research integrates modern and traditional forms of medicine to provide accessible and affordable healthcare.

The Medicity Expanded Access Program Physicians

Dr. Vijay Kher - Chairman, Division of Nephrology, Kidney & Urology Institute
Dr. Vijay Kher is currently Chairman, Division of Nephrology, Medanta Kidney & Urology Institute. Dr. Kher has established Academic & Clinical departments of Nephrology at Shere-Kashmir, Institute of Medical Sciences in Srinagar, SGPGIMS Lucknow, Apollo Hospitals, New Delhi, Fortis group of hospitals NCR, Delhi & now at Medanta. His research interests are kidney transplantation (clinical immunosuppression, pre emptive kidney transplantation & steroid free immunosuppression, cost-containment), progression of renal disease, acute kidney injury and glomerulonephritis. An astute clinician, a teacher par excellence and a keen researcher, Dr. Kher combines these assets with a friendly and inclusive demeanor to inspire the Nephrology fraternity in India by his professional dedication, academic excellence and social responsibility. He has been awarded fellowships of National Academy of Medical Sciences, Royal College of Physicians Edinburg & Indian Society of Nephrology. Dr. Kher has published more than 150 papers in peer-reviewed journals, 24 book chapters and has edited 5 books.

Dr. Randhir Sud - Chairman, Medanta Institute of Digestive & Hepatobiliary Sciences
Dr. Sud is Chairman of The Medanta Institute of Digestive & Hepatobiliary Sciences, which is a dedicated facility for patients with gastrointestinal, liver, pancreatic and biliary diseases, There are multiple treatment options for a disease and to provide the best available treatment to patients, this Institute has devised protocols where medical, surgical and allied teams jointly decide patient treatments and management.

About Aethlon Medical, Inc.

The Aethlon Medical mission is to create innovative medical devices that address unmet medical needs in cancer, infectious disease, and other life-threatening conditions. Our Aethlon ADAPT™ System is a revenue-stage technology platform that provides the basis for a new class of therapeutics that target the selective removal of disease enabling particles from the entire circulatory system. The Aethlon ADAPT™ product pipeline includes the Aethlon Hemopurifier® to address infectious disease and cancer; HER2osome™ to target HER2+ breast cancer, and a medical device being developed under a contract with DARPA that would reduce the incidence of sepsis in combat-injured soldiers and civilians. For more information, please visit www.aethlonmedical.com.

Certain statements herein may be forward-looking and involve risks and uncertainties. Such forward-looking statements involve assumptions, known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of Aethlon Medical, Inc. to be materially different from any future results, performance, or achievements expressed or implied by the forward-looking statements. Such potential risks and uncertainties include, without limitation, that this expanded treatment program will augment the company's current government contract revenue stream, that the FDA will not approve the initiation of the Company's clinical programs or provide market clearance of the company's products, future human studies whether revenue or non-revenue generating of the Aethlon ADAPT™ system or the Aethlon Hemopurifier® as an adjunct therapy to improve patient responsiveness to established cancer or hepatitis C therapies or as a standalone cancer or hepatitis C therapy, the Company's ability to raise capital when needed, the Company's ability to complete the development of its planned products, the Company's ability to manufacture its products either internally or through outside companies and provide its services, the impact of government regulations, patent protection on the Company's proprietary technology, product liability exposure, uncertainty of market acceptance, competition, technological change, and other risk factors. In such instances, actual results could differ materially as a result of a variety of factors, including the risks associated with the effect of changing economic conditions and other risk factors detailed in the Company's Securities and Exchange Commission filings. The Company undertakes no obligation to publicly update or revise any forward-looking statements, whether as a result of new information, future events, or otherwise.

Contacts:

James A. Joyce
Chairman and CEO
858.459.7800 x301
jj@aethlonmedical.com

Jim Frakes
Chief Financial Officer
858.459.7800 x300
jfrakes@aethlonmedical.com

Marc Robins
877.276.2467
mr@aethlonmedical.com

SOURCE Aethlon Medical, Inc.

Source

May 8, 2012

Aethlon Medical Reports Undetectable Hepatitis C Virus (HCV) in Genotype 1, Genotype 3, and Genotype 5 Patients Treated with Hemopurifier® Therapy

PR-Logo-Newswire

PRESS RELEASE

May 8, 2012, 9:30 a.m. EDT

SAN DIEGO, May 8, 2012 /PRNewswire via COMTEX/ -- Aethlon Medical, Inc. , the pioneer in developing selective therapeutic filtration devices to address infectious disease, cancer and other life-threatening conditions, reported today that the presence of Hepatitis C virus (HCV) is currently undetectable in all infected patients that have been treated with the Aethlon Hemopurifier® in combination with peginterferon+ribavirin (PR) drug therapy and monitored for at least ninety days.

In a study conducted at the Medanta Medicity Institute (Medicity), HCV-infected individuals were enrolled to receive up to three, six-hour Hemopurifier® treatments during the first three days of PR drug therapy. The Medicity is a $360 million multi-specialty medical institute established to be a premier center for medical tourism in India. The Aethlon Hemopurifier® is a first-in-class medical device that selectively targets the rapid clearance of HCV from the entire circulatory system to improve benefit, dose, duration and tolerability of drug therapies.

In the Medicity study, Aethlon reported that Hemopurifier® therapy has been well tolerated and without device-related adverse events in nine treated patients. Of these nine patients, six patients were infected with HCV genotype-1; two patients were infected with HCV genotype-3; and one patient was infected with HCV genotype-5. Of the nine reported patients, seven have been monitored for more than ninety days. All seven currently maintain undetectable viral load, including three patients who have been monitored for 48-weeks. Two patients initiated Hemopurifier® therapy on April 18th and April 30th, and therefore have not yet been monitored for extended viral load suppression.

The Immediate Impact of Hemopurifier® Therapy

In addition to demonstrating safety and early efficacy against multiple HCV genotypes, a clinical objective of the Medicity study was to evaluate whether the Hemopurifier® could accelerate HCV eradication to levels associated with treated patients who achieve the highest rate of viral cure, including individuals that previously failed or relapsed PR drug regimens. In the study, Aethlon observed that viral load depletion during the Hemopurifier® + PR drug therapy phase was greatest in hard-to-treat genotype-1 patients with high viral load. In one treated patient, baseline HCV RNA dropped from 5,800,000 IU/ml to 1,840 IU/ml when measured after the third day of Hemopurifier® + PR therapy, representing a 3.49 log or 99.96% reduction of viral load. In another patient, baseline HCV RNA dropped from 8,760,000 IU/ml to 4,665 IU/ml when measured on day-3, representing a 3.27 log or 99.96% reduction. By contrast, a moderate viral load Hemopurifier® patient with baseline HCV RNA of 1,340,000 IU/ml dropped to 54,900 IU/ml when measured on day-3, representing a 1.38 log or 95.9% reduction.

As a point of reference, the landmark IDEAL Study of 3,070 HCV genotype-1 patients documented that less than 5% of treated patients will achieve a 2-log or greater reduction of viral load when measured 7-days after the start of PR drug therapy. While the IDEAL study did not report day-3 viral load, a 2-log+ reduction at day-7 is a rare occurrence defined as an immediate virologic response (IVR). The IDEAL study confirms the viral cure or sustained virologic response rate of IVR patients to be greater than 90%. Based on Medicity treatment outcomes, Hemopurifier® therapy had a significant impact in accelerating HCV eradication in high viral load patients.

Capacity of the Hemopurifier® to Capture HCV During Treatment

As the result of discussions with reviewers at the Center for Devices and Radiological Health (the FDA branch responsible for approving medical devices in the US), Aethlon recently expanded the Medicity protocol to establish a data point that would quantify the amount of HCV captured within the Hemopurifier® during a single treatment. In one analyzed cartridge, researchers recovered and measured that approximately 300 billion (300,000,000,000) copies of HCV had been captured within the Hemopurifier® during a single six-hour treatment at the Medicity. Beyond the impact of inhibiting progeny virus replication, the viral capture data point defines the contribution Hemopurifier® therapy can provide to current and future antiviral drug treatment regimens. Aethlon considers this data point to be unprecedented as the previous ability to measure the benefit of HCV therapies has primarily been limited to measuring changes in the amount of virus that can be detected in circulation.

Next Steps

As a result of Hemopurifier® + PR therapy outcomes, Aethlon has requested permission from the Medicity internal review board (IRB) to begin offering Hemopurifier® therapy to HCV-infected individuals that reside outside of India. The Company has also requested IRB permission to expand the treatment protocol to allow for up to seven Hemopurifier® treatments to be administered during the first week of PR drug therapy. Based on previous three-treatment protocol outcomes, Aethlon anticipates an expanded Hemopurifier® dosing schedule could establish new milestones for early undetectable viral load achievement. The Company also disclosed it will resubmit an investigational device exemption (IDE) which incorporates the Medicity data as part of its effort to gain FDA approval to initiate clinical programs in the U.S.

It is estimated that approximately 4 million Americans and 170 million people worldwide are infected with HCV, which leads to chronic liver disease or cirrhosis, and is the leading cause of liver transplant in the U.S. To date, almost 100 Hemopurifier® treatments have been administered in human studies. Previously, studies of the Hemopurifier® have been conducted at the Apollo, Fortis, and Sigma New Life hospitals in India. These studies demonstrated that Hemopurifier® therapy could safely reduce viral load in both HIV and HCV-infected dialysis patients without the administration of antiviral drug therapies. The Medicity study represents the first Hemopurifier® study in non-dialysis patients. In vitro studies have further validated the ability of the Hemopurifier® to capture a broad-spectrum of viral pathogens classified as bioterror or pandemic threats.

About Aethlon Medical

The Aethlon Medical mission is to create innovative medical devices that address unmet medical needs in cancer, infectious disease, and other life-threatening conditions. Our Aethlon ADAPT(TM) System is a revenue-stage technology platform that provides the basis for a new class of therapeutics that target the selective removal of disease enabling particles from the entire circulatory system. The Aethlon ADAPT(TM) product pipeline includes the Aethlon Hemopurifier® to address infectious disease and cancer; HER2osome(TM) to target HER2+ breast cancer, and a medical device being developed under a contract with DARPA that would reduce the incidence of sepsis in combat-injured soldiers and civilians. For more information, please visit www.aethlonmedical.com .

Certain statements herein may be forward-looking and involve risks and uncertainties. Such forward-looking statements involve assumptions, known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of Aethlon Medical, Inc. to be materially different from any future results, performance, or achievements expressed or implied by the forward-looking statements. Such potential risks and uncertainties include, without limitation, that the FDA will not approve the initiation of the Company's clinical programs or provide market clearance of the company's products, future human studies of the Aethlon ADAPT(TM) system or the Aethlon Hemopurifier® as an adjunct therapy to improve patient responsiveness to established cancer therapies, the Company's ability to raise capital when needed, the Company's ability to complete the development of its planned products, the Company's ability to manufacture its products either internally or through outside companies and provide its services, the impact of government regulations, patent protection on the Company's proprietary technology, product liability exposure, uncertainty of market acceptance, competition, technological change, and other risk factors. In such instances, actual results could differ materially as a result of a variety of factors, including the risks associated with the effect of changing economic conditions and other risk factors detailed in the Company's Securities and Exchange Commission filings. These statements, including patient data, are based on information currently available to the Company's management and future patient results may differ from present results. The Company undertakes no obligation to publicly update or revise any forward-looking statements, whether as a result of new information, future events, or otherwise.

Contacts:

James A. JoyceChairman and CEO858.459.7800 x301jj@aethlonmedical.com 

Jim FrakesChief Financial Officer858.459.7800 x300jfrakes@aethlonmedical.com

Marc Robins877.276.2467mr@aethlonmedical.com 

SOURCE Aethlon Medical, Inc.

Source

April 24, 2012

Aethlon Medical Note: An Unprecedented Data Point, The Single-Treatment Capture of Hepatitis C Virus (HCV) by the Aethlon Hemopurifier®

hemo

PRESS RELEAAE

April 24, 2012, 9:30 a.m. EDT

SAN DIEGO, April 24, 2012 /PRNewswire via COMTEX/ -- Aethlon Medical, Inc., today released the following note authored by its Chairman and CEO, Jim Joyce.

The gold standard for determining drug therapy benefit against infectious disease targets is to measure changes in patient viral load, otherwise known as the amount of virus that is detectable in circulation. Specific to Hepatitis C virus (HCV), the best predictor of whether a treated patient will achieve a long-term viral cure is the period of time it takes to first achieve undetectable viral load. We recently disclosed that the administration of Hemopurifer® therapy during the first three days of peginterferon+ribavirin (PR) drug therapy resulted in observations of immediate (IVR) and rapid virologic responses (RVR) in hard-to-treat genotype-1 patients. IVR is a 2-log or 100 fold reduction of HCV viral load at day-7. Such a response correlates with 90+% viral cure rates, yet is observed in less than 5% of patients who receive PR therapy alone. RVR is defined as undetectable HCV viral load at day-30 of treatment and correlates with viral cure rates of 86.2%, which is observed in only 10.35% of patients who initiate PR therapy.

In this note, I will discuss an unprecedented data point that further validates the potential of Hemopurifier® therapy to improve the benefit of current interferon-based and emerging all-antiviral drug regimens. This same data point also provides further evidence that may help to explain our recent IVR and RVR treatment observations.

As the result of a collaborative discussion with reviewers at the Center for Devices and Radiological Health (the FDA branch responsible for approving medical devices in the US), our researchers initiated an effort to establish a protocol that would quantify the amount of HCV captured within our Hemopurifier® during a single treatment application. This would first entail a post-treatment preparation for each Hemopurifier®, which would then need to be frozen until ready for shipment on dry ice. This process is still being perfected as two of the first three cartridges analyzed were badly cracked. The next step was to establish a repeatable protocol methodology that would allow biological fluid to be eluted from within the Hemopurifier® so that PCR, the standard for measuring viral copies, could be utilized to validate and quantify the capture of HCV during treatment. The results were compelling.

In the two cracked cartridges referenced above, our researchers recovered and measured the capture of 145 million and 353 million copies of HCV. However, when the fully intact Hemopurifier® was analyzed, our researchers recovered and measured that 300 billion (300,000,000,000) copies of HCV had been captured during a single six-hour treatment. For those viruses captured, the possibility of continued progeny virus replication was eliminated. I applaud our research team for establishing this unprecedented data point, which defines the contribution our Hemopurifier® can provide to current and future HCV treatment regimens. Additionally, this data point serves as a model for capture capacity of other disease enhancing particles, whether they be associated with cancer, sepsis or other viral conditions.

About Aethlon Medical

The Aethlon Medical mission is to create innovative medical devices that address unmet medical needs in cancer, infectious disease, and other life-threatening conditions. Our Aethlon ADAPT(TM) System is a revenue-stage technology platform that provides the basis for a new class of therapeutics that target the selective removal of disease enabling particles from the entire circulatory system. The Aethlon ADAPT(TM) product pipeline includes the Aethlon Hemopurifier® to address infectious disease and cancer; HER2osome(TM) to target HER2+ breast cancer, and a medical device being developed under a contract with the Defense Advanced Research Projects Agency (DARPA) that would reduce the incidence of sepsis in combat-injured soldiers and civilians. For more information, please visit www.aethlonmedical.com .

Certain of the statements herein may be forward-looking and involve risks and uncertainties. Such forward-looking statements involve assumptions, known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of Aethlon Medical, Inc. to be materially different from any future results, performance, or achievements expressed or implied by the forward-looking statements. Such potential risks and uncertainties include, without limitation, the ability for the Company to derive business partnerships or future revenue streams using the Aethlon ADAPT(TM) system including the ability to capture hepatitis c virus, there is no assurance that FDA will approve the initiation of the company's clinical programs or provide market clearance of the company's products, the ability to achieve the goals set out in the DARPA contract, future human studies of the Aethlon Hemopurifier® as an adjunct therapy to improve patient responsiveness to established cancer therapies, the company's ability to raise capital when needed, the Company's ability to complete the development of its planned products, the Company's ability to manufacture its products either internally or through outside companies and provide its services, the impact of government regulations, patent protection on the Company's proprietary technology, product liability exposure, uncertainty of market acceptance, competition, technological change, and other risk factors. In such instances, actual results could differ materially as a result of a variety of factors, including the risks associated with the effect of changing economic conditions and other risk factors detailed in the Company's Securities and Exchange Commission filings.

Contacts:

James A. JoyceChairman and CEO858.459.7800 x301jj@aethlonmedical.com

Jim FrakesChief Financial Officer858.459.7800 x300jfrakes@aethlonmedical.com

John P. SalvadorDirector, Communications858.459.7800 x307jps@aethlonmedical.com

SOURCE Aethlon Medical, Inc.

Source

February 7, 2012

Aethlon Medical to Present Hepatitis C (HCV) Treatment Technology at the 32nd Annual Dialysis Conference

PR-Logo-Newswire

PRESS RELEASE

Feb. 7, 2012, 8:15 a.m. EST

SAN DIEGO, Feb. 7, 2012 /PRNewswire via COMTEX/ -- Aethlon Medical, Inc. , the pioneer in developing selective therapeutic filtration devices to address infectious disease, cancer and other life-threatening conditions, announced today that a presentation of the Aethlon Hemopurifier® to treat Hepatitis C virus (HCV) and other infectious disease conditions will occur at the upcoming 32nd Annual Dialysis Conference to be held on February 26-28 at the Henry B. Gonzalez Convention Center in San Antonio, Texas. The presentation, which will be given by Aethlon President Rod Kenley, is scheduled to begin at 9:20 am CST on February 28th.

The Hemopurifier® is a first-in-class medical device that provides rapid real-time clearance of circulating HCV as well as immunosuppressive proteins shed by the virus. The goal of therapy is to improve benefit, dose, duration and tolerability of current and future drug therapies without introducing drug toxicity and interaction risks. Included among the Hemopurifier® treatment opportunities in HCV are the estimated 300,000 infected dialysis patients that currently live with the virus. As a result of their health-compromised end-stage renal condition, dialysis patients are often unable to tolerate HCV drug therapy dosing and duration, resulting in suboptimal treatment outcomes. To optimize outcomes, Hemopurifier® therapy would be combined with reduced dose drug therapy and conveniently administered during regular dialysis, which is scheduled three times per week with each treatment lasting four hours. In regards to the size of the overall HCV treatment opportunity, it is estimated that approximately 4 million Americans and 170 million people worldwide are infected with HCV, which leads to chronic liver disease or cirrhosis, and is the leading cause of liver transplant in the U.S.

On February 1, 2012, Aethlon reported that intermittent administration of Hemopurifier® therapy in just the first three days of standard of care peginterferon+ribavirin (PR) drug therapy resulted in immediate and rapid virologic responses in genotype-1 infected HCV patients not on dialysis. An immediate virologic response (IVR) represents a 2-log or 100 fold reduction of HCV RNA at day-7 of therapy and rapid virologic response (RVR) is defined as undetectable HCV RNA at day-30 of the 48-week PR regimen. Average HCV RNA reduction during the three day Hemopurifier® + PR treatment window was 98.79%. In previous studies of HCV-infected dialysis patients, average per treatment reductions of HCV RNA exceeded 50% when Hemopurifier® therapy was included in series with four-hour dialysis sessions in patients not receiving HCV drug therapy.

Aethlon also anticipates that Hemopurifier® therapy could benefit emerging all-antiviral drug cocktails, which face the challenge of overcoming the rate at which viruses attain drug resistance through rapid mutation. The development of drug-resistant strains can occur quickly owing to the extraordinarily high rate of HCV replication. The clearance of circulating hepatitis C virions, including mutant strains, would inhibit the continued replication of drug-resistant viruses and decrease the likelihood of early onset resistance to emerging all-antiviral strategies.

The Extract-1 Study Protocol

The results reported by Aethlon on February 1st, represent interim data from the first three patients treated with Hemopurifier® therapy under the Extract-1 study protocol, which was initiated in the fall of 2011. Under the Extract-1 study protocol, hard-to-treat genotype 1 HCV patients are enrolled to receive three 6-hour applications of Hemopurifier® therapy during the first three days of standard of care PR therapy. On day one of the Extract-1 protocol, PR therapy is initiated within one hour of first Hemopurifer® therapy completion. Hemopurifier® therapy is then administered again once daily for the next two days in combination with PR therapy. During the Hemopurifier® treatment periods, patients are free to watch movies, read books, and perform other tasks in the comfort of a clinic setting.

Clinical Endpoint Assessments

The aim of the Extract-1 study protocol is to assess the safety and clinical impact of intermittent Hemopurifier® therapy when combined with the first three days of peginterferon+ribavirin (PR) standard-of-care. To date, Hemopurifier® therapy in Extract-1 treated patients has been well tolerated and without device-related adverse events during the Hemopurifier® + PR treatment period. At present, the reported data of the Extract-1 study is not statistically significant and should be considered preliminary. Changes in HCV RNA levels are measured with the Roche Cobas TaqMan assay, which has a quantification limit of 15 IU per milliliter (iu/ml). In addition to measuring changes in HCV RNA, the Extract-1 study protocol will quantify the amount of HCV captured within Hemopurifier® treatment cartridges. The goal of PR treatment is to establish a sustained virologic response (SVR), defined as undetectable HCV RNA 24 weeks after completion of therapy. Primary clinical endpoints of the Extract-1 study measure the impact of Hemopurifier® therapy during the initial phase of PR therapy. Each clinical endpoint is based on changes in HCV RNA from baseline viral load measurements taken prior to Hemopurifier® + PR therapy initiation. These endpoints include:

Day Three (3): the change in HCV RNA from baseline to the end of the Hemopurifier® + PR treatment phase;

Day Seven (7): the change in HCV RNA 7 days from initial baseline. A drop of HCV RNA greater than 2 logs at day 7 is known as an Immediate Virologic Response (IVR). Based on the landmark IDEAL Study of 3,070 HCV genotype-1 patients receiving PR therapy, IVR achievement correlates with 90+% SVR rates, yet is observed in less than 5% of patients;

Day 30: the change in HCV RNA 30 days from initial baseline. Undetectable HCV RNA at day 30 is known as a Rapid Virologic Response (RVR). Based on the IDEAL Study, RVR achievement correlates with an SVR likelihood of 86.2%, which is observed in only 10.35% of patients.

Day 3 Results

Patient E-1.03: Baseline HCV RNA dropped from 5,800,000 IU/ml to 1,840 IU/ml when measured on day 3, representing a 3.49 log reduction. HCV RNA reduction during the 3-day Hemopurifier® + PR treatment phase accounted for 99.96% of the overall HCV RNA reduction reported at day-30.

Patient E-1.02: Baseline HCV RNA dropped from 199,500 IU/ml to 31,550 IU/ml when measured on day 3, representing a 0.80 log reduction. HCV RNA reduction during the 3-day Hemopurifier® + PR treatment phase accounted for 84.21% of the overall HCV RNA reduction reported at day-30.

Patient E-1.01: Baseline HCV RNA dropped from 1,340,000 IU/ml to 54,900 IU/ml when measured on day 3, representing a 1.38 log reduction. HCV RNA reduction during the 3-day Hemopurifier® + PR treatment phase accounted for 95.90% of the overall HCV RNA reduction reported at day-30.

Day 7 Results

On average, the treated patients achieved 2.24 log HCV RNA reduction from baseline at day-7, which is beyond the 2 log reduction that defines the IVR criteria achieved in less than 5% of PR treated patients.

Patient E-1.03: Baseline HCV RNA dropped from 5,800,000 IU/ml to 234 IU/ml when measured on day 7, representing a 4.39 log reduction.

Patient E-1.02: Baseline HCV RNA dropped from 199,500 IU/ml to 17,300 IU/ml when measured on day 7, representing a 1.06 log reduction.

Patient E-1.01: Baseline HCV RNA dropped from 1,340,000 IU/ml to 24,400 IU/ml when measured on day 7, representing a 1.74 log reduction.

Day 30 Results

Two of the three patients achieved a RVR at day 30, which is normally achieved in only 10.35% of patients receiving PR therapy, yet correlates with a 86.2% SVR versus a 30.4% SVR in patients who fail to achieve a RVR. Based on the IDEAL study, it would normally require the enrollment of approximately 20 PR treated patients to accomplish 2 RVR outcomes. It should also be noted that patient E-1.02 missed RVR achievement by 25 iu/ml.

Patient E-1.03: Baseline HCV RNA dropped from 5,800,000 IU/ml to undetectable (<15 IU/ml) when measured on day 30, representing a 5.58 log reduction.

Patient E-1.02: Baseline HCV RNA dropped from 199,500 IU/ml to 40 IU/ml when measured on day 30, representing a 3.69 log reduction.

Patient E-1.01: Baseline HCV RNA dropped from 1,340,000 IU/ml to undetectable (<15 IU/ml) when measured on day 30, representing a 4.95 log reduction.

Beyond high SVR rates, RVR achievement also provides HCV infected individuals the opportunity to reduce PR duration from 48 to 24 weeks (6-month reduction) in RVR patients that maintain undetectable HCV RNA through week 12 of PR therapy. RVR patients are also unlikely to discontinue PR therapy as a result of a non-virological response, which represents the primary reason why 46% of PR therapy patients don't complete their treatment regimen.

RVR achievement also plays a pivotal role in curbing treatment relapse, defined as undetectable HCV RNA at PR completion that again becomes detectable in the 24-week window after therapy completion. As reflected in the IDEAL study, the time to first undetectable HCV RNA correlates with the incidence of treatment relapse. Approximately 50% of patients who achieve complete HCV suppression for the first time by week 24 of therapy suffer from treatment relapse, while less than 10% of RVR patients relapse from therapy.

The Extract-1 study is being conducted at Medanta, The Medicity Institute (Medicity), a $360 million multi-specialty medical institute recently established to be a premier center for medical tourism in India. The principal investigator of the study is Vijay Kher, M.D., Chairman of the Department of Nephrology at the Medanta Kidney & Urology Institute. Dr. Kher previously served as the principal investigator of Hemopurifier® therapy studies conducted at the Apollo and Fortis hospitals in Delhi, India.

Based on the initial Extract-1 study outcomes, Aethlon will seek permission to open up the treatment study to HCV infected individuals who reside outside of India. The company also plans to expand its GMP manufacturing capabilities and upon quantification of HCV capture within Hemopurifier® treatment cartridges, will resubmit an Investigational Device Exemption (IDE) that will request FDA permission to initiate treatment studies in the U.S. The Company is also interested in collaborative clinical opportunities aimed at determining the synergistic effects of Hemopurifier® therapy combined with non-interferon based drug regimens.

About Aethlon Medical

The Aethlon Medical mission is to create innovative medical devices that address unmet medical needs in cancer, infectious disease, and other life-threatening conditions. Our Aethlon ADAPT(TM) System is a revenue-stage technology platform that provides the basis for a new class of therapeutics that target the selective removal of disease enabling particles from the entire circulatory system. The Aethlon ADAPT(TM) product pipeline includes the Aethlon Hemopurifier® to address infectious disease and cancer; HER2osome(TM) to target HER2+ breast cancer, and a medical device being developed under a contract with the Defense Advanced Research Projects Agency (DARPA) that would reduce the incidence of sepsis in combat-injured soldiers and civilians. For more information, please visit www.aethlonmedical.com .

Certain of the statements herein may be forward-looking and involve risks and uncertainties. Such forward-looking statements involve assumptions, known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of Aethlon Medical, Inc. to be materially different from any future results, performance, or achievements expressed or implied by the forward-looking statements. Such potential risks and uncertainties include, without limitation, the ability to recruit genotype-1 hepatitis C infected patients, including dialysis patients, positive results at the conclusion of the Extract-1 study, the ability to attain permission and to attract patients outside of India, the company's ability to expand its GMP manufacturing capabilities, the Company's ability to attain clinical collaborations to determine the Hemopurifier's® effect with non-interferon based drug regimens, there is no assurance that FDA will approve the initiation of the Company's clinical programs or provide market clearance of the company's products, future human studies of the Aethlon Hemopurifier® as an adjunct therapy to improve patient responsiveness to established cancer therapies, the company's ability to raise capital when needed, the Company's ability to complete the development of its planned products, the Company's ability to manufacture its products either internally or through outside companies and provide its services, the impact of government regulations, patent protection on the Company's proprietary technology, product liability exposure, uncertainty of market acceptance, competition, technological change, and other risk factors. In such instances, actual results could differ materially as a result of a variety of factors, including the risks associated with the effect of changing economic conditions and other risk factors detailed in the Company's Securities and Exchange Commission filings.

Contacts:

James A. JoyceChairman and CEO858.459.7800 x301jj@aethlonmedical.com 

Jim FrakesChief Financial Officer858.459.7800 x300jfrakes@aethlonmedical.com 

John P. SalvadorDirector, Communications858.459.7800 x307jps@aethlonmedical.com 

SOURCE Aethlon Medical, Inc.

Source

February 1, 2012

Aethlon Medical Reports Immediate and Rapid Virologic Responses in Hepatitis C (HCV) Patients Receiving Hemopurifier® Treatment Protocol

PR-Logo-Newswire

PRESS RELEASE

Feb. 1, 2012, 7:33 a.m. EST

SAN DIEGO, Feb. 1, 2012 /PRNewswire via COMTEX/ -- Aethlon Medical, Inc.  the pioneer in developing selective therapeutic filtration devices to address infectious disease, cancer and other life-threatening conditions, reported today that the administration of Hemopurifier® therapy during the first three days of standard of care peginterferon+ribavirin (PR) drug therapy has demonstrated both immediate and rapid virologic responses in genotype-1 infected HCV patients. An immediate virologic response (IVR) represents a 2-log or 100 fold reduction of HCV RNA at day-7 of therapy and rapid virologic response (RVR) is defined as undetectable HCV RNA at day-30 of the 48-week PR regimen. Average HCV RNA reduction during the three day Hemopurifier® + PR treatment window was 98.79%.

It is estimated that approximately 4 million Americans and 170 million people worldwide are infected with HCV, which leads to chronic liver disease or cirrhosis, and is the leading cause of liver transplant in the U.S. The Hemopurifier® provides rapid real-time clearance of circulating HCV yielding the potential to improve benefit, dose, duration and tolerability of drug therapies without the introduction of drug toxicity and interaction risks. In previous Hemopurifier® studies, average HCV RNA reductions exceeded 50% during four-hour treatment periods without the administration of drug therapy.

"We are extremely pleased with our interim treatment outcomes, which highlight the synergistic potential of Hemopurifier® and drug therapy working in concert to overcome a disease condition," stated Aethlon Chairman and CEO, Jim Joyce. "In addition to our expansive opportunity in hepatitis C, we continue to advance parallel strategies to address HIV, cancer, and sepsis."

Beyond the opportunity to improve PR standard-of-care therapy, Hemopurifier® therapy may also benefit emerging all-antiviral drug cocktails, which face the challenge of overcoming the rate at which viruses attain drug resistance through rapid mutation. The development of drug-resistant strains can occur quickly owing to the extraordinarily high rate of HCV replication. The clearance of circulating hepatitis C virions, including mutant strains, would inhibit the continued replication of drug-resistant viruses and decrease the likelihood of early onset resistance to emerging all-antiviral strategies.

The Extract-1 Study Protocol

The reported results represent interim data from the first three patients treated with Hemopurifier® therapy under the Extract-1 study protocol, which was initiated in the fall of 2011. The clinical site location previously administered Hemopurifier® therapy to non-genotype 1 HCV patients under various treatment schedules. Under the Extract-1 study protocol, hard-to-treat genotype 1 HCV patients are enrolled to receive three 6-hour applications of Hemopurifier® therapy during the first three days of standard of care PR therapy. On day one of the Extract-1 protocol, PR therapy is initiated within one hour of first Hemopurifer® therapy completion. Hemopurifier® therapy is then administered again once daily for the next two days in combination with PR therapy. During the Hemopurifier® treatment periods, patients are free to watch movies, read books, and perform other tasks in the comfort of a clinic setting.

Clinical Endpoint Assessments

The aim of the Extract-1 study protocol is to assess the safety and clinical impact of intermittent Hemopurifier® therapy when combined with the first three days of peginterferon+ribavirin (PR) standard-of-care. To date, Hemopurifier® therapy in Extract-1 treated patients has been well tolerated and without device-related adverse events during the Hemopurifier® + PR treatment period. At present, the reported data of the Extract-1 study is not statistically significant and should be considered preliminary. Changes in HCV RNA levels are measured with the Roche Cobas TaqMan assay, which has a quantification limit of 15 IU per milliliter (iu/ml). In addition to measuring changes in HCV RNA, the Extract-1 study protocol will quantify the amount of HCV captured within Hemopurifier® treatment cartridges. The goal of PR treatment is to establish a sustained virologic response (SVR), defined as undetectable HCV RNA 24 weeks after completion of therapy. Primary clinical endpoints of the Extract-1 study measure the impact of Hemopurifier® therapy during the initial phase of PR therapy. Each clinical endpoint is based on changes in HCV RNA from baseline viral load measurements taken prior to Hemopurifier® + PR therapy initiation. These endpoints include:

Day Three (3): the change in HCV RNA from baseline to the end of the Hemopurifier® + PR treatment phase;

Day Seven (7): the change in HCV RNA 7 days from initial baseline. A drop of HCV RNA greater than 2 logs at day 7 is known as an Immediate Virologic Response (IVR). Based on the landmark IDEAL Study of 3,070 HCV genotype-1 patients receiving PR therapy, IVR achievement correlates with 90+% SVR rates, yet is observed in less than 5% of patients;

Day 30: the change in HCV RNA 30 days from initial baseline. Undetectable HCV RNA at day 30 is known as a Rapid Virologic Response (RVR). Based on the IDEAL Study, RVR achievement correlates with an SVR likelihood of 86.2%, which is observed in only 10.35% of patients.

Day 3 Results

Patient E-1.03: Baseline HCV RNA dropped from 5,800,000 IU/ml to 1,840 IU/ml when measured on day 3, representing a 3.49 log reduction. HCV RNA reduction during the 3-day Hemopurifier® + PR treatment phase accounted for 99.96% of the overall HCV RNA reduction reported at day-30.

Patient E-1.02: Baseline HCV RNA dropped from 199,500 IU/ml to 31,550 IU/ml when measured on day 3, representing a 0.80 log reduction. HCV RNA reduction during the 3-day Hemopurifier® + PR treatment phase accounted for 84.21% of the overall HCV RNA reduction reported at day-30.

Patient E-1.01: Baseline HCV RNA dropped from 1,340,000 IU/ml to 54,900 IU/ml when measured on day 3, representing a 1.38 log reduction. HCV RNA reduction during the 3-day Hemopurifier® + PR treatment phase accounted for 95.90% of the overall HCV RNA reduction reported at day-30.

Day 7 Results

On average, the treated patients achieved 2.24 log HCV RNA reduction from baseline at day-7, which is beyond the 2 log reduction that defines the IVR criteria achieved in less than 5% of PR treated patients.

Patient E-1.03: Baseline HCV RNA dropped from 5,800,000 IU/ml to 234 IU/ml when measured on day 7, representing a 4.39 log reduction.

Patient E-1.02: Baseline HCV RNA dropped from 199,500 IU/ml to 17,300 IU/ml when measured on day 7, representing a 1.06 log reduction.

Patient E-1.01: Baseline HCV RNA dropped from 1,340,000 IU/ml to 24,400 IU/ml when measured on day 7, representing a 1.74 log reduction.

Day 30 Results

Two of the three patients achieved a RVR at day 30, which is normally achieved in only 10.35% of patients receiving PR therapy, yet correlates with a 86.2% SVR versus a 30.4% SVR in patients who fail to achieve a RVR. Based on the IDEAL study, it would normally require the enrollment of approximately 20 PR treated patients to accomplish 2 RVR outcomes. It should also be noted that patient E-1.02 missed RVR achievement by 25 iu/ml.

Patient E-1.03: Baseline HCV RNA dropped from 5,800,000 IU/ml to undetectable (<15 IU/ml) when measured on day 30, representing a 5.58 log reduction.

Patient E-1.02: Baseline HCV RNA dropped from 199,500 IU/ml to 40 IU/ml when measured on day 30, representing a 3.69 log reduction.

Patient E-1.01: Baseline HCV RNA dropped from 1,340,000 IU/ml to undetectable (<15 IU/ml) when measured on day 30, representing a 4.95 log reduction.

Beyond high SVR rates, RVR achievement also provides HCV infected individuals the opportunity to reduce PR duration from 48 to 24 weeks (6-month reduction) in RVR patients that maintain undetectable HCV RNA through week 12 of PR therapy. RVR patients are also unlikely to discontinue PR therapy as a result of a non-virological response, which represents the primary reason why 46% of PR therapy patients don't complete their treatment regimen.

RVR achievement also plays a pivotal role in curbing treatment relapse, defined as undetectable HCV RNA at PR completion that again becomes detectable in the 24-week window after therapy completion. As reflected in the IDEAL study, the time to first undetectable HCV RNA correlates with the incidence of treatment relapse. Approximately 50% of patients who achieve complete HCV suppression for the first time by week 24 of therapy suffer from treatment relapse, while less than 10% of RVR patients relapse from therapy.

The Extract-1 study is being conducted at Medanta, The Medicity Institute (Medicity), a $360 million multi-specialty medical institute recently established to be a premier center for medical tourism in India. The principal investigator of the study is Vijay Kher, M.D., Chairman of the Department of Nephrology at the Medanta Kidney & Urology Institute. Dr. Kher previously served as the principal investigator of Hemopurifier® therapy studies conducted at the Apollo and Fortis hospitals in Delhi, India.

Based on the initial Extract-1 study outcomes, Aethlon will seek permission to open up the treatment study to HCV infected individuals who reside outside of India. The company also plans to expand its GMP manufacturing capabilities and upon quantification of HCV capture within Hemopurifier® treatment cartridges, will resubmit an Investigational Device Exemption (IDE) that will request FDA permission to initiate treatment studies in the U.S. The Company is also interested in collaborative clinical opportunities aimed at determining the synergistic effects of Hemopurifier® therapy combined with non-interferon based drug regimens.

About Aethlon Medical

The Aethlon Medical mission is to create innovative medical devices that address unmet medical needs in cancer, infectious disease, and other life-threatening conditions. Our Aethlon ADAPT(TM) System is a revenue-stage technology platform that provides the basis for a new class of therapeutics that target the selective removal of disease enabling particles from the entire circulatory system. The Aethlon ADAPT(TM) product pipeline includes the Aethlon Hemopurifier® to address infectious disease and cancer; HER2osome(TM) to target HER2+ breast cancer, and a medical device being developed under a contract with the Defense Advanced Research Projects Agency (DARPA) that would reduce the incidence of sepsis in combat-injured soldiers and civilians. For more information, please visit www.aethlonmedical.com .

Certain of the statements herein may be forward-looking and involve risks and uncertainties. Such forward-looking statements involve assumptions, known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of Aethlon Medical, Inc. to be materially different from any future results, performance, or achievements expressed or implied by the forward-looking statements. Such potential risks and uncertainties include, without limitation, the ability to recruit genotype-1 hepatitis C infected patients, positive results at the conclusion of the Extract-1 study, the ability to attain permission and to attract patients outside of India, the company's ability to expand its GMP manufacturing capabilities, the Company's ability to attain clinical collaborations to determine the Hemopurifier's® effect with non-interferon based drug regimens, there is no assurance that FDA will approve the initiation of the Company's clinical programs or provide market clearance of the company's products, future human studies of the Aethlon Hemopurifier® as an adjunct therapy to improve patient responsiveness to established cancer therapies, the company's ability to raise capital when needed, the Company's ability to complete the development of its planned products, the Company's ability to manufacture its products either internally or through outside companies and provide its services, the impact of government regulations, patent protection on the Company's proprietary technology, product liability exposure, uncertainty of market acceptance, competition, technological change, and other risk factors. In such instances, actual results could differ materially as a result of a variety of factors, including the risks associated with the effect of changing economic conditions and other risk factors detailed in the Company's Securities and Exchange Commission filings.

Contacts:

James A. JoyceChairman and CEO858.459.7800 x301jj@aethlonmedical.com 

Jim FrakesChief Financial Officer858.459.7800 x300jfrakes@aethlonmedical.com 

John P. SalvadorDirector, Communications858.459.7800 x307jps@aethlonmedical.com 

SOURCE Aethlon Medical, Inc.

Source

August 26, 2010

Aethlon Medical Announces Approval of Hepatitis C Virus (HCV) Treatment Program

AETHLON MEDICAL HEMOPURIFIER Aethlon Hemopurifier. (PRNewsFoto/Aethlon Medical, Inc.) SAN DIEGO, CA UNITED STATES

SAN DIEGO, Aug. 26 /PRNewswire-FirstCall/ -- Aethlon Medical, Inc. (OTC Bulletin Board: AEMD), the pioneer in developing therapeutic filtration devices to address infectious disease and cancer, announced today that the Medanta Independent Ethics Committee (MIEC) at Medanta, The Medicity Institute (Medicity) has approved a treatment program entitled: "Use of the Aethlon Hemopurifier® in Treating Chronic HCV Infection in Combination with Standard of Care (SOC) Drug Therapy." The Medicity is a $360 million multi-specialty medical institute recently established on a 43-acre campus to be a premier center of medical tourism in India. The Aethlon Hemopurifier® is the first medical device to selectively target the removal of infectious viruses and immunosuppressive proteins from the entire circulatory system. A clinical goal of the Aethlon-Medicity study will be to demonstrate that the Hemopurifier® is able to accelerate the benefit of HCV standard of care (SOC) drug regimens. Therapeutic filtration at the outset of SOC improves early virus reduction kinetics to levels associated with that of patients most likely to achieve a sustained viral response, which is the goal of HCV therapy. Additionally, lower quantities of HCV in circulation at the outset of SOC correlate with increased cure rates.

(Photo: http://photos.prnewswire.com/prnh/20090325/LA88762LOGO-b)
(Photo: http://www.newscom.com/cgi-bin/prnh/20090325/LA88762LOGO-b)

"We are grateful for this opportunity to show the pharmaceutical industry, infected patients, and shareholders that our Hemopurifier® can enhance the capabilities of drug regimens without adding additional drug toxicity and interaction risks", stated Aethlon Chairman and CEO, Jim Joyce. "Beneficial outcomes will set the stage for the early commercialization of our technology and should recalibrate industry viewpoints on addressing infectious disease conditions."

Upon the demonstration of early treatment benefit, Aethlon plans to advance commercialization through the Medicity and other regional treatment centers in India. In this regard, the company has entered into an agreement with GVK Biosciences (GVK BIO) to expand the opportunity for Aethlon to commercialize its Hemopurifier® treatment technology at three to five new clinical centers in India. GVK BIO is Asia's leading Discovery Research and Development organization. The HCV treatment opportunity for Aethlon is significant as greater than 20 million of the estimated 180 million people infected with HCV worldwide reside in India. Based on patient feedback, Aethlon also believes that citizens of other nations may chose to travel to India to seek treatments that could resolve their HCV infection.

Aethlon further disclosed that the principal investigator of the clinical program, which has been registered with the Clinical Trials Registry of India, will be Vijay Kher, M.D., Chairman of the Department of Nephrology at the Medanta Kidney & Urology Institute. Dr. Kher previously served as the principal investigator of Hemopurifier® human studies to treat HCV at the Apollo and Fortis Hospital in Delhi, India. These studies demonstrated safety and effectiveness of the Hemopurifier® to reduce viral load in the absence of drug therapy. Patients enrolled in the Medicity study will receive a maximum of six Hemopurifier® treatments within the first week of initiating SOC drug therapy. In addition to monitoring for improved acceleration of viral load reduction at the outset of SOC, another primary endpoint will focus on rapid viralogic response (RVR) which is defined as undetectable viral load 30 days after SOC initiation. On average, approximately 15% of patients who initiate SOC therapy achieve a RVR. Yet, those able to achieve a RVR have a greater than 88% likelihood of achieving a sustained viralogic response. The initiation of patient enrollment for the Medicity is conditional upon maintaining the treatment protocols approved by the MIEC and that clinical endpoint / efficacy assessment be further clarified by the principal investigator. Aethlon has also agreed to give consideration to compensating enrolled patients for lost wages while receiving Hemopurifier® treatment and other consideration should a material adverse event occur as a result of Hemopurifier® therapy.

About Aethlon Medical

At Aethlon Medical, we create revolutionary devices to address infectious disease and cancer. Our devices are designed to be novel platform solutions that fill therapeutic voids or aid in disease diagnosis and monitoring.

Our Hemopurifier® is the first medical device to selectively target the removal of infectious viruses and immunosuppressive proteins from the entire circulatory system. We recently discovered that our Hemopurifier® captures tumor-secreted exosomes that suppress the immune system of those afflicted with cancer. Prior to this discovery, a therapeutic strategy to directly inhibit or reverse the immunosuppressive destruction caused by exosomes did not exist in cancer care. By eliminating this mechanism, we believe our Hemopurifier® can fill an unmet clinical need and provide the benefit of an immune-based therapy without adding drug toxicity or interaction risks to established and emerging treatment strategies.

Human studies have documented the ability of our Hemopurifier® to safely reduce viral load in both Hepatitis-C virus (HCV) and Human Immunodeficiency Virus (HIV) infected patients without the administration of antiviral drugs. However, our initial clinical and commercialization focus is to establish our Hemopurifier® as an adjunct therapy to enhance the benefit of both infectious disease and cancer treatment regimens. In this regard, we plan to commercialize our Hemopurifier® in India as we advance our clinical strategies in the United States and the European Union. In vitro studies conducted by government and non-government research institutes have also verified that our Hemopurifier® has broad-spectrum capabilities against bioterror and emerging pandemic threats. These studies have confirmed the capture of Dengue Hemorrhagic Virus, Ebola Hemorrhagic Virus, Lassa Hemorrhagic Virus, West Nile Virus, H5N1 Avian Influenza Virus, 2009 H1N1 Influenza Virus, the reconstructed Spanish Flu of 1918 Virus, and Monkeypox Virus, which serves as a model for human Smallpox infection.

As a therapeutic device, the Hemopurifier® provides us with a pipeline into four significant market opportunities:

1. Cancer: A treatment candidate to improve patient responsiveness to established cancer therapies by removing immunosuppressive exosomes from circulation.

2. Hepatitis-C Virus (HCV): As an adjunct therapy to accelerate viral load reduction at the outset of standard of care drug regimens.

3. Human Immunodeficiency Virus (HIV): Provides a potential therapeutic option for HIV-infected individuals to manage disease progression once they become resistant to antiviral drug regimens.

4. Bioterror and Pandemic Threats: Represents the most advanced broad-spectrum strategy to address untreatable bioterror and emerging pandemic threats.

The Hemopurifier® is an expansive multi-patented platform technology whose mechanism of action can be leveraged to provide therapeutic, diagnostic, and biomarker discovery solutions. As a therapeutic, the Hemopurifier® is a single-use disposable cartridge designed for implementation within the established infrastructure of dialysis machines and other blood circulatory pumps already located in hospitals and clinics worldwide.

In design, our Hemopurifier® is a selective filtration device containing affinity agents that tightly bind to high-mannose structures unique to the surface of exosomes produced by cancer and glycoproteins residing on the envelope of viruses. These agents are immobilized around approximately 2800 porous hollow fibers that run the interior length of our device. The resulting design provides us the novel ability to separate both exosome and viral targets away from blood cells so they can then be selectively and permanently removed from the circulatory system. In application, blood circulation is established into the Hemopurifier® via a catheter or other blood access device. Once blood flow has been established, treatment benefit is immediate as the entire circulatory system can pass through the Hemopurifier® in as little as 15 minutes.

Our wholly owned subsidiary, Exosome Sciences, Inc. (ESI) is focused on the development of exosome-targeted products and services that improve cancer diagnosis, provide post-treatment cancer surveillance, and aid in the discovery of biomarkers that allow doctors to optimize patient therapy. Additional information regarding Aethlon Medical and Exosome Sciences can be accessed online at http://www.aethlonmedical.com/.

Certain of the statements herein may be forward-looking and involve risks and uncertainties. Such forward-looking statements involve assumptions, known and unknown risks, uncertainties and other factors which may cause the actual results, performance or achievements of Aethlon Medical, Inc. to be materially different from any future results, performance, or achievements expressed or implied by the forward-looking statements. Such potential risks and uncertainties include, without limitation, the capability of the Hemopurifier® to reduce viral loads and other disease conditions or to identify or treat disease conditions such as cancer, including the ability to capture exosomes and the impact that potential ability may have on disease conditions, the Company's ability to raise capital when needed, the Company's ability to complete the development of its planned products, the ability of the Company to obtain FDA and other regulatory approvals permitting the sale of its products, the ability to achieve commercialization in India as a result of the proposed treatment program at Medanta, The Medicity Institute, whether successful or not, the Company's ability to manufacture its products either internally or through outside companies and provide its services, the impact of government regulations, patent protection on the Company's proprietary technology, product liability exposure, uncertainty of market acceptance, competition, technological change, and other risk factors. In such instances, actual results could differ materially as a result of a variety of factors, including the risks associated with the effect of changing economic conditions and other risk factors detailed in the Company's Securities and Exchange Commission filings.

Contacts:

James A. Joyce
Chairman, CEO
858.459.7800 x301
jj@aethlonmedical.com

John P. Salvador
Director, Communications & Investor Relations
858.459.7800 x307
jps@aethlonmedical.com

Jon Cunningham
RedChip Companies, Inc.
800.733.2447 x107
jon@redchip.com

SOURCE Aethlon Medical, Inc.

RELATED LINKS
http://www.aethlonmedical.com/

Source